Model
|
RS-232
USB
|
5330AL
5330ALU |
Capacity |
|
3000VA/1800W |
Input |
Voltage
|
110/115/120VAC
or 220/230/240VAC |
| Voltage
Range |
86VAC~144VAC
or 172VAC ~288VAC (+/-25%) |
| Frequency |
|
Output |
Voltage
Regulation
(Batt. Mode)
|
110/115/120VAC
or 220/230/240VAC +/-10% |
| Frequency |
50Hz
or 60Hz +/-1Hz |
| Waveform |
Simulated
Sinewave |
| Transfer
Time |
<
6ms (Typical) |
| Outlet |
Outlets:
IEC-320/
NEMA 5-15R |
4/4 |
Battery
|
Battery
Type
|
12V/12AH*4pcs |
Recharge
Time
|
5Hrs
to 90% after complete discharge |
| User's
Replacement |
Yes |
| Battery
Protection |
Over
discharge protection & Short circuit protection by
fuse |
Advanced
Battery Management
|
Yes |
Battery
Back-up
Time
|
It depends
on connecting loads |
Function
|
Display(LCD)
|
LCD display
for AC normal,Back-up,AVR protection,Load and Battery
level, Overload and UPS cut off |
Alarm
|
Buzzer
on for Back-up mode,Battery low,Overload |
Output
Short
Protection |
AC fuse
and Electronic circuit(Line mode);Electronic circuit (Back-up
mode) |
| Communication
Port(RS-232) |
Shutdown
software for Windows 95/98/NT/2000/ME/XP/Vista |
Modem/Phone
Protection
|
RJ-11/RJ-45 |
Lightning/
Surge Protection
|
240joules |
AVR
(Auto. Voltage Regulation)
|
Boost/Buck |
DC
Start Function
|
Yes |
Auto.
Restart UPS
|
Yes |
Over/Under
Voltage
Protection
|
Yes |
Environment
|
Safety
Standard |
CE (EN50091-1,EN62040-1-1) |
EMC
Standard
|
FCC Part
15 Class B,CE (EN50091-2,EN55011,EN61000-3-2,EN61000-3-3) |
Operating
Temperature
|
0 ~ 40
°C |
Relative
Humidity
|
0 ~ 95%,
non-condensing |
Audible
Noise
|
<
40dB at 1M |
Physical |
Dimension(D*W*H)
|
408*143*197mm |
| Net
Weight |
15Kgs |
| Dimension(D*W*H)-Battery
Bank |
408*143*197mm |
| Net
Weight |
20Kgs |
Design,Manufacture,Services |
ISO 9001-2000 |
Warranty |
1 year |