UPS
Online UPS

On-line UPS 9300LB HV Tower 1-3KVA

IDEAL-9300LB 1-3KVA series is true sine wave double conversion On-line UPS tower type model that provides output power factor 0.8 for high performance and efficiency.
With Microprocessor control design, it lowers the defective rate of UPS to guarantee high reliability and to protect any critical applications.
Individual PDU module is used as Power Distribution Unit in conjunction with IDEAL-9300LB 3KVA UPS system,which will be more convenient and efficient when UPS needs maintenance service.

  • 9300LB Series 1-3KVA (Tower Cabinet / Comprehensive LCD Display)

    High performance true double conversion On Line UPS 1-3KVA
    Intelligent Solt (SNMP) + USB multiple communications
    Individual power distribution unit (PDU) maintenance bypass switch (Optional for 3KVA)
    External battery bank to extend back-up time (Optional)
    Microprocessor control guarantees high reliability
    Low heat dissipation in long time operation
    Emergency power-off function (EPO)
    Automatic self-testing function
    High efficiency mode (ECO mode)
    Output voltage regulation < 2%
    Power management software
    Output power factor 0.8
    Wide input range
    Fan speed control
    DC start
  • MODEL IDEAL-9301LB IDEAL-9301LBE IDEAL-9303LB IDEAL-9303LBE
    CAPACITY 1KVA/0.8KW 3KVA/2.4KW
    INPUT
    Voltage 200/208/220/230/240Vac
    Voltage Range 200/208/220/230/240Vac: 110 - 300Vac
    Frequency 50Hz or 60Hz (Auto Sensing)
    THDi < 5% at full Load
    OUTPUT
    Voltage 200/208/220/230/240Vac
    Voltage Regulation 200/208/220/230/240Vac: +/- 2%
    Frequency (Battery Mode) 200/208/220/230/240Vac: 50Hz or 60Hz +/- 0.2Hz
    Waveform Pure Sinewave
    THD 200/208/220/230/240Vac: < 3% (Linear Load), < 5% (Non-linear Load)
    Crest Ratio 3:1
    EFFICIENCY
    To AC Mode 200/208/220/230/240Vac: > 88% at Full Load and Battery Full Charged
    To Battery Mode 200/208/220/230/240Vac: > 85% at Full Load and Battery Full Charged
    To ECO Mode 200/208/220/230/240Vac: > 93% at Full Load and Battery Full Charged
    BATTERY
    Voltage 36VDC 200/208/220/230/240Vac: 96VDC
    Type 12V/7AH*3pcs Extendable 96VDC: 12V/7AH*8pcs Extendable
    Recharge Time 5Hrs to 90% Depend on Capacity of External Battery 5Hrs to 90% Depend on Capacity of External Battery
    TRANSFER TIME
    Line Mode to Battery Mode 0ms
    Inverter to Bypass, ECO Mode <4ms
    ECO Mode to Inverter <10ms
    DISPLAY
    LCD Display Input, Output, Load, Battery, Mode/Fault/Warning code, Inverter operating, Bypass operating, Output voltage and frequency and Bypass disable / enable
    selection information
    AUDIBLE ALARM
    Battery Mode

    Beeps Every 4 Seconds

    Battery Low Sounding Every Second
    Overload Sounding Twice Every Second
    UPS Fault Continuously Beeping
    COMMUNICATIONS
    Interface (Port)
    USB Port
    Intelligent Slot Slot for SNMP or AS400 card (Optional)
    EPO Emergency Power Off
    ENVIRONMENT  
    Temperature 100/110/115/120VAC: 0 - 40℃ ; 200/208/220/230/240VAC: 0 - 45℃
    Humidity 20-90%, non-condensing
    Acoustic Noise 100/110/115/120VAC: < 45dB at 1M; 200/208/220/230/240VAC: < 50dB at 1M
    PHYSICAL  
    Dimension(D*W*H) 420*145*230mm 560*193*346mm
    *Product specifications are subject to change without further notice.